User Manual
Table Of Contents
- LRP76 Long Range Passive Reader/Writer
- Table of Contents
- Getting Started
- Mechanical Specifications
- Power and Electrical Interface
- Configuration Menu
- Standard RFID Interface
- 5.1 Introduction
- 5.2 Command Timeout Values
- 5.3 Address Blocks
- 5.4 ABx Error Codes
- 5.5 Command Descriptions
- 5.6 ABx Standard Commands
- 5.6.1 Command 4 (04 Hex): Tag Fill
- 5.6.2 Command 5 (05 Hex): Block Read
- 5.6.3 Command 6 (06 Hex): Block Write
- 5.6.4 Command 7 (07H): Read Tag Serial Number
- 5.6.5 Command 8 (08 Hex): Tag Search
- 5.6.6 Command D (0D Hex): Start/Stop Continuous Block Read
- 5.6.7 Command E (0EH) Read SN and Data
- 5.6.8 Command F (0FH) Start/Stop Continuous Read SN and Data
- 5.7 ABx Fast Commands
- 5.7.1 ABx Command Packet Structure
- 5.7.2 Command 4 (04 Hex): Tag Fill
- 5.7.3 Command 5 (05 Hex): Block Read
- 5.7.4 Command 6 (06 Hex): Block Write
- 5.7.5 Command 7 (07H): Read Tag Serial Number
- 5.7.6 Command 8 (08 Hex): Tag Search
- 5.7.7 Command D (0D Hex): Start/Stop Continuous Block Read
- 5.7.8 Command E (0EH) Read SN and Data
- 5.7.9 Command F (0FH) Start/Stop Continuous Read SN and Data
- Technical Specifications
- Models and Accessories
- ASCII Chart
Standard RFID Interface
LRP76 Long Range Passive Reader/Writer 23
EXAMPLE
Reads 8 bytes of data from the tag starting at address 01H. A timeout
of 2 seconds (07D0H = 2000 x 1 msec increments) is set for the
completion of the Block Read.
Command from the Host Response from the LRP76
MSB LSB Remarks MSB LSB Remarks
AAH 05H Perform Command 5 AAH 05H Command Echo
00H 01H Start Address = 0001H 00H 52H Read Data 1 = 52H
00H 08H Read Block Length = 8 bytes
(0008H)
00H 46H Read Data 2 = 46H
07H D0H Timeout value 00H 49H Read Data 3 = 49H
FFH FFH Message Terminator 00H 44H Read Data 4 = 44H
00H 20H Read Data 5 = 20H
00H 54H Read Data 6 = 54H
00H 61H Read Data 7 = 61H
00H 67H Read Data 8 = 67H
FFH FFH Message Terminator