User's Manual

Table Of Contents
7.2.1 Downloading Firmware to the Interface Board
To download new software to the interface board, select "X" from the Moni
-
tor Menu shown above to retain existing configuration settings or "Z" if you
wish to overwrite configuration settings with factory defaults. In most cases
you will want to retain existing configuration settings and should use the X
command to download new firmware.
IMPORTANT:
It is not necessary to download firmware into the unit unless instructed to do
so by Escort Memory Systems technical support personnel.
————————————————————————————-
| HMS/LRP Rd/Wrt Controller with DeviceNet & Serial I/O. |
| (c) 2000 Escort Memory Systems, a Datalogic Co. |
————————————————————————————-
Commands:
I <cr> ———— Display Configuration Info
E <cr> ———— Edit Configuration Sub-menu
Z <cr> ———— Download Firmware Hex File (config defaults)
X <cr> ———— Download Firmware Hex File (retain config)
RESET ———— To enter Run Mode (exit monitor)
>x
Note: "X" is the recommended option for new firmware download by the user. No download option will
overwrite the DeviceNet serial number set at the factory.
*:-D Initiate download now (do not restart prior to RESET msg.)*
Copyright © 2000 Escort Memory Systems
LRP830-Series Long-Range Passive Reader/Writer
147