7.2.2 Downloading with the EC Emulation Program
If you are using the terminal emulator "EC" provided by Escort Memory
Systems (EMS), do the following from EC to download the new software:
1. Perform ALT-F to enter the file menu.
2. Select "download" from the menu.
3. Select "ASCII" from the pop-up window.
4. Specify the path/name of the hex file provided by Escort Memory
Systems.
When the download is complete, you will be prompted to reset
the LRP830 with the following message:
<:-> RESET NOW...
5. Repower the LRP830.
7.2.3 Display Interface Board Configuration
Parameters
The following display reflects the current configuration parameters that are
stored in the unit's non-volatile flash ROM. Some of the parameters can be
modified via the Configuration Edit option "E" (see next Section).
SW1 positions 7 and 8 can be used to set the DeviceNet baud rate as fol
-
lows:
00 = 125k (default)
01 = 250k
10 = 500k
Please refer to the ODVA DeviceNet Specification for additional informa
-
tion.