User's Manual

Table Of Contents
7.2.4 Interface Board Configuration Editor
Note: the following menu can be attained via "Y" (above) or selecting "E"
from the Monitor Menu (above). These are the recommended parameters,
however, it is likely that A and/or B (below) may require modification ac
-
cording to customer requirements.
<= LRP830 INTERFACE-BOARD CONFIGURATION MENU =>
Enter Parameter # to Change:
===== Std DeviceNet =====
90 A. 830 Tx Msg Size (0-254)
90 B. 830 Rx Msg Size (0-254)
0 C. DevNet Protocol (Poll=0,Strobe=1)
D. DeviceNet Serial# 04 99 12 34 (hex)
===== LRP830 Specific =====
2 1. Device Type (GENeric: 0=norm, 1=rev; HDR: 2=n, 3=r)
Y 2. ABx separation (Y/N)
N 3. Buf Flush Enable (Y/N)
200 4. Buf Flush Delay (0-9999)
SELECTION 1-C? (Ctrl-C Exits)
When you wish to exit the interface board configuration menu, enter
"CTRL-C." The following prompt will appear which is responded with "n"
in this example.
Update Flash ROM (y/n)?> n [:-( Flash ROM *Not* Updated )-:]
{-:) Please Reset LRP830 to enter RUN mode (:-}
{HALTED}
<RESET>
The LRP830 must now be reset or power cycled to enable the unit to enter
"RUN" mode.
Copyright © 2000 Escort Memory Systems
150 LRP830-Series Long-Range Passive Reader/Writer