fore downloading another version of software, display and record the current
configuration settings. Then download the new software version. Set switch
5 (on the main board) on and apply power to initialize the configuration pa
-
rameters to their default states. When the LEDs stop flashing, turn Switch 5
to Off and press the reset switch. Enter the Configuration Menu and re-enter
any non-default configuration parameters.
When you select 3 from the Main Menu, the LRP830 will prompt you to
begin the download.
*** Download DSP Firmware***
Press a key to start Downloading
After you have pressed a key, the LRP830 will display:
Send the Intel Hex file. Downloading now.
Send the new firmware via your terminal emulation program in ASCII text
or Hexadecimal format. The firmware will be automatically transferred to
the DSP Flash Memory. Wait 10 seconds after the download is complete
before resetting the LRP830.
Record: 750
Download OK
File Transfer to DSP
Blocco 24/24
DSP Flash Programming...
New Firmware Transferred to DSP
WARNING:
Do not download INTERFACE BOARD firmware to the main board.
IMPORTANT:
It is not necessary to download firmware into the unit unless instructed to do
so by Escort Memory Systems technical support personnel.
5.5 Exit to Operating Mode
This option is available if you wish to use temporary, unsaved, configuration
parameters. The unsaved options you have selected will be used until the
LRP830 is reset and the saved parameters are restored.
Copyright © 2000 Escort Memory Systems
LRP830-Series Long-Range Passive Reader/Writer