User's Manual

Table Of Contents
EXAMPLE:
Reads 8 bytes of data from the tag starting at address 0001H. A timeout of 2
seconds (07D0H = 2000 x 1 msec increments) is set for the completion of
the Block Read.
Copyright © 2000 Escort Memory Systems
54 LRP830-Series Long-Range Passive Reader/Writer
Command from Host
MSB LSB Remarks
AAH 05H Perform command 5
00H 01H Start Address = 0001H
00H 08H Read Block Length = 8 bytes
(0008H)
07H D0H Timeout Value
FFH FFH Message Terminator
Response from LRP830
MSB LSB Remarks
AAH 05H Command echo
00H 52H Read Data1=52H
00H 46H Read Data2=46H
00H 49H Read Data3=49H
00H 44H Read Data4=44H
00H 20H Read Data5=20H
00H 54H Read Data6=54H
00H 61H Read Data7=61H
00H 67H Read Data8=67H
FFH FFH Message Terminator