User's Manual

Table Of Contents
EXAMPLE:
Writes 4 bytes of data to the tag starting at address 0020H. A timeout of 2
seconds (07D0H = 2000 x 1 msec increments) is set for the completion of
the Block Write.
Copyright © 2000 Escort Memory Systems
56 LRP830-Series Long-Range Passive Reader/Writer
Command from Host
MSB LSB Remarks
AAH 06H Perform Command 6
00H 20H Start Address = 0020H
00H 04H Write Length = 4 bytes
07H D0H Timeout Value
00H 52H Write Data1=52H
00H 46H Write Data2=46H
00H 49H Write Data3=49H
00H 44H Write Data4=44H
FFH FFH Message Terminator
Response from LRP830
MSB LSB Remarks
AAH 06H Command echo
FFH FFH Message Terminator