User's Manual

Table Of Contents
EXAMPLE:
Writes 4 bytes of data to the tag starting at address 0000H. A timeout of 2
seconds (07D0H = 2000 x 1 msec increments) is set for the completion of
the Block Write.
Copyright © 2000 Escort Memory Systems
LRP820-Series Long-Range Passive Reader/Writer
97
Command from Host
Field Contents
Header
<STX><STX>
02H
02H
Command Size 00H
0BH
Command Code 06H
Start address 00H
00H
Block Size 00H
04H
Timeout,
2 seconds
07H
D0H
Data to write to
address 0000H
52H
Data to write to
address 0001H
46H
Data to write to
address 0002H
49H
Data to write to
address 0003H
44H
Checksum EEH
Terminators <ETX> 03H
Response from LRP820
Field Contents
Header
<STX><STX>
02H
02H
Response Size 00H
01H
Command Echo 06H
Checksum F8H
Terminators <ETX> 03H