User's Manual

Table Of Contents
ABxF Command 95 (95H): SN Block Read
DESCRIPTION
Read a block of data from an RFID tag.
DISCUSSION
This command is used to read segments of data from contiguous areas of tag
memory. The timeout value is given in 1 msec increments and can have a
value of 1EH to FFFEH (65,534 ms). When the timeout is set to 0, the
LRP820 will return a syntax error. A special error packet is sent if the time
-
out expires.
If the read range exceeds the last tag address, the LRP820 will return an
invalid format error message (error code 21H).
Field Content
Header <STX><STX>
Command Size Packet length in bytes excluding the header, command size, checksum and
terminator bytes.
Command 95H
Family ID Tag Family ID - 00H = all tags
Anticollision Index Number of tags expected
Start Address 2-byte value for the starting tag address
Block Size 2-byte value for the length of the read in number of bytes
Timeout 2-byte value for timeout in 1 ms units. (1EH - FFFEH)
Tag Serial Number 8-byte tag serial number
Checksum Optional Checksum
Terminator <ETX>
Copyright © 2000 Escort Memory Systems