User's Manual

Table Of Contents
The ASCII character string for a fill of 32 bytes, from address 0 with 55H
value, timeout 5 sec., follows.
Copyright © 2000 Escort Memory Systems
LRP820-Series Long-Range Passive Reader/Writer
141
Command from Host
Field
ASCII
Hex
Value
ASCII
String
Header
<STX><STX>
02H STX
02H STX
Command Size 30H 0
30H 0
30H 0
38H 8
Command 30H 0
34H 4
Start Address 30H 0
30H 0
30H 0
30H 0
Fill Length 30H 0
30H 0
32H 2
30H 0
Timeout Value 31H 1
33H 3
38H 8
38H 8
Data Byte Value 35H 5
35H 5
Checksum 45H E
33H 3
Terminators <ETX> 03H ETX
Response from LRP820
Field ASCII
Hex
Value
ASCII
String
Header
<STX><STX>
02H STX
02H STX
Response Size 30H 0
30H 0
31H 1
30H 0
Command Echo 30H 0
34H 4
Checksum 46H F
41H A
Terminators <ETX> 03H ETX