User's Manual
Table Of Contents
- TABLE OF CONTENTS
- 1 GETTING STARTED 1
- 2 MECHANICAL SPECIFICATIONS 4
- 3 POWER AND ELECTRICAL INTERFACE 14
- Power from the MUX32 bus and from an ex ter nal power sup ply 26
- 3.9 LED In di ca tors 27
- 4 SERIAL AND BUS COMMUNICATIONS 29
- 5 MENU CONFIGURATION 34
- 6 RFID INTERFACE 41
- 6.1 In tro duc tion 41
- 6.2 ABx Er ror Codes 44
- 6.3 Anticollision Com mands 47
- 6.4 ABx Stan dard Pro to col 49
- ABxS Com mand 4 (04H): Fill Tag 49
- ABxS Com mand 5 (05H): Block Read 51
- ABxS Com mand 6 (06H): Block Write 53
- ABxS Com mand 7 (07H): Read Tag Se rial Num ber 55
- ABxS Com mand 8 (08H): Tag Search 56
- ABxS Com mand D (0DH): Con tin u ous Block Read 57
- ABxS Com mand 10 (10H): Set Out put 60
- ABxS Com mand 11 (11H): In put Sta tus 62
- ABxS Com mand 84 (84H): Fill Tag All 64
- ABxS Com mand 85 (85H): Block Read All 66
- ABxS Com mand 86 (86H): Block Write All 68
- ABxS Com mand 87 (87H): Read Tag SN All 70
- ABxS Com mand 88 (88H): Tag Search All 72
- ABxS Com mand 89 (89H): EAS Set/Re set All 73
- ABxS Com mand 8A (8AH): EAS Start/Stop 75
- ABxS Com mand 8D (8DH): Con tin u ous Read All 77
- ABxS Com mand 8E (8EH): Mem ory Lock All 79
- ABxS Com mand 94 (94H): SN Fill 81
- ABxS Com mand 95 (95H): SN Block Read 83
- ABxS Com mand 96 (96H): SN Block Write 85
- ABxS Com mand 97 (97H): SN Block Read All 87
- 6.5 ABx Fast Pro to col 89
- ABx Com mand Packet Struc ture: 89
- Com mand/Re sponse Size 90
- Checksum 91
- ABxF Com mand 4 (04H): Fill Tag 92
- ABxF Com mand 5 (05H): Block Read 94
- ABxF Com mand 6 (06H): Block Write 96
- ABxF Com mand 7 (07H): Read Tag Se rial Num ber 98
- ABxF Com mand 8 (08H): Tag Search 100
- ABxF Com mand D (0DH): Con tin u ous Block Read 101
- ABxF Com mand 10 (10H): Set Out put 104
- ABxF Com mand 11 (11H): In put Sta tus 106
- ABxF Com mand 84 (84H): Fill All 108
- ABxF Com mand 85 (85H): Block Read All 110
- ABxF Com mand 86 (86H): Block Write All 112
- ABxF Com mand 87 (87H): Read Tag SN All 114
- ABxF Com mand 88 (88H): Tag Search All 116
- ABxF Com mand 89 (89H): EAS Set/Re set All 118
- ABxF Com mand 8A (8AH): EAS Start/Stop 120
- ABxF Com mand 8D (8DH): Con tin u ous Read All 123
- ABxF Com mand 8E (8EH): Mem ory Lock All 126
- ABxF Com mand 94 (94H): SN Fill 128
- ABxF Com mand 95 (95H): SN Block Read 130
- ABxF Com mand 96 (96H): SN Block Write 132
- ABxF Com mand 97 (97H): SN Block Read All 134
- 6.6 ABx ASCII Pro to col 138
![](/manual/balluff/lrp800/user-s-manual-english/images/img-35.png)
4 SERIAL AND BUS COMMUNICATIONS
4.1 Serial Interfaces
The LRP820 has RS232 and RS422 available on the COM1 serial port.
COM2 is configured for RS232 communications and is reserved for down
-
loading programs to the LRP820 and for setting up the configuration
parameters.
Both RS232 and RS422 interfaces are opto-isolated. The RS422 interface
is specially suitable for long cable, noisy environment links.
The specification for the COM1 interface follows:
n
Baud rate: 1200, 2400, 4800, 9600, 19200, 38400 bps
n
Data: 7, 8
n
Parity: Even, Odd, None
n Handshake: None, Xon/Xoff
The specification for the COM2 interface follows:
n
Baud rate: 1200, 2400, 4800, 9600, 19200 bps
n
Data: 7, 8
n
Parity: Even, Odd, None
n
Handshake: None, Xon/Xoff
Copyright © 2000 Escort Memory Systems
LRP820-Series Long-Range Passive Reader/Writer
29