User's Manual

Table Of Contents
Start Address (0-47)
Enter the tag address where you want the read to begin.
Length (1-48)
Enter the length of the read you wish the LRP820 to perform. Make certain
that the length value does not exceed the number of possible addresses fol
-
lowing the starting tag address. Entering a read length of 0 will disable Con
-
tinuous Read Mode.
Delay Between Identical Decodes (0-60)
The Delay Between Identical Decodes parameters can have a value of 0 to
60 seconds. When the Delay Between Identical Decodes is set to 0, the
LRP820 will continuously read AND transmit tag data to the host. This can
flood the buffers and cause communication errors and data loss.
Raw Read Response?
If you have selected ABx Fast or ABx ASCII, you have the option of strip-
ping the command protocol from the data and adding a terminator to sepa-
rate the data packets. You can choose a CR (0DH) or CR/LF (0DH, 0AH) to
terminate the data.
Set RF Communication
The LRP820 should be configured with the default (0) Fast Mode.
*** Set RF Communication ***
RF Communication? [0] Fast Mode* [1] Standard Mode 0
Save Changes to EEPROM? [0] No [1] Yes
Restore Factory Defaults
It is often helpful during troubleshooting to restore the LRP820 to known
default values. To do so, select 1from this menu.
*** Restore Factory Defaults ***
Restore Factory Default? [0] No [1] Yes
The restored defaults will be saved to the EEPROM. The communication
defaults can also be restored by placing the main board DIP switch number 5
in the ON position and then restarting the LRP820. After you have saved
any changes, you must re-initialize the LRP820 with switch 5 in the OFF
position.
Copyright © 2000 Escort Memory Systems
38 LRP820-Series Long-Range Passive Reader/Writer