User's Manual

Table Of Contents
ABxS Command 94 (94H): SN Fill
DESCRIPTION
Fills only the RFID tag specified by serial number with a one byte value
over multiple contiguous addresses.
DISCUSSION
This command is commonly used to clear an RFID tag's memory. It writes a
one byte value repetitively across a specified range of tag addresses. Only
the tag with the specified serial number will be affected by this command.
The LRP820 will return a response after the successful fill operation or
when the timeout expires.
The fill function requires a Family ID and an Anticollision Index, one data
value byte, a starting address, and a fill length. Then the command lists the
serial numbers of the tag to be filled. It fills the specified tag with the data
value byte, starting at the specified start address for the specified number of
consecutive bytes. When Fill Length is set to 0, the LRP820 will write fill
data from the start address to the end of the tags memory.
The timeout value is given in 1 msec increments and can have a value of
1EH to FFFEH (65,534 ms). When the timeout is set to 0, the LRP820 will
return a syntax error. It returns a response when done or when the timeout
expires.
Field Remarks
Command Command number in hex preceded by AAH
Family Code Tag Family ID - 00H = all tags
Anticollision index Number of tags-in-field expected
Start Address The tag address where the fill will start
Fill Length The number of tag addresses to be filled
Timeout Timeout value given in 1 ms units (1EH - FFFEH)
Tag Serial Number The 8-byte serial number
Data Value Byte The byte used to fill
Message Terminator FFFFH
Copyright © 2000 Escort Memory Systems
LRP820-Series Long-Range Passive Reader/Writer
81