User's Manual

Table Of Contents
EXAMPLE:
Reads 2 bytes of data from the tag starting at address 0001H. A timeout of 2
seconds (07D0H = 2000 x 1 msec increments) is set for the completion of
the SN Block Read All. The Family ID byte is set to zero so all tags will be
read. The Anticollision Index is set to 2 so 4-8 tags are expected. Two tags
respond with read data.
Copyright © 2000 Escort Memory Systems
88 LRP820-Series Long-Range Passive Reader/Writer
Command from Host
MSB LSB Remarks
AAH 97H Perform Command 97
00H 02H Tag Family 00/ Index 2
00H 01H Start Address
00H 02H Read Length
07H D0H Timeout
FFH FFH Message Terminator
Response from LRP820
MSB LSB Remarks
AAH 97H Command Echo/Tag 1
00H 10H SN byte 1/Tag 1
00H 43H SN byte 2/Tag 1
00H 6CH SN byte 3/Tag 1
00H 73H SN byte 4/Tag 1
00H 92H SN byte 5/Tag 1
00H C0H SN byte 6/Tag 1
00H D6H SN byte 7/Tag 1
00H 54H SN byte 8/Tag 1
00H 30H Data byte 1/Tag 1
00H 31H Data byte 2/Tag 1
FFH FFH Terminator/ Tag 1
AAH 97H Command Echo/Tag 2
00H 08H SN byte 1/Tag 2
00H 0AH SN byte 2/Tag 2
00H 81H SN byte 3/Tag 2
00H 18H SN byte 4/Tag 2
00H 23H SN byte 5/Tag 2
00H CCH SN byte 6/Tag 2
00H D0H SN byte 7/Tag 2
00H EFH SN byte 8/Tag 2
00H 40H Data byte 1/Tag 2
00H 41H Data byte 2/Tag 2
FFH FFH Terminator/ Tag 2
AAH FFH Command end
02H 08H Ntags/Status
FFH FFH Message Terminator