User guide

Document # I17792 Rev G
© Copyright
BAND-IT-IDEX, Inc. 2009
All rights reserved
www.BAND-IT-IDEX.com
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver, CO 80216-0307 USA
P: 1-800-525-0758 F: 1-800-624-3925
14 of 38
IT2000-AB
1/4” Junior
®
Tool
Clamp Installation:
When installing a clamp, a random visual check to verify the presence of a locking lip
after the clamp has been applied is recommended. The lip is the locking element
of an installed band. The IT2000 forms a fold into the band at the buckle edge with
the knife. By controlling and monitoring the items that are needed to form a good
lock, an operator can help insure that the clamp will be applied correctly without
having to inspect every assembly.
These items are:
Adequate air pressure and volume (see page 4, 6)
Setting the tool air pressure (see page 4, 6)
Following recommended PM Schedule (see page 21)
Fixture mounting the tool properly (see page10-13 )
For Best Performance and to Extend Tool Life:
Follow preventative maintenance and parts replacement instructions (page 21) at
appropriate service intervals.
Do not remove factory applied lubrication from inside tool unless performing a
thorough maintenance procedure and then replacing with fresh Lubricant
immediately.
Do not use degreaser in the tool body.
Do not spray any lubricant or cleaner into the Quick Connect Air Couplings.
Use nominal recommended tension setting (listed on page 4, 6). Higher pressure
may not result in a tighter clamp, but increases the likelihood of clamp tail jamming
and premature worn parts.
Do not over-tighten Knife Pin access screws. Over tightening of these screws may
result in stripping screw threads.
For maintenance beyond what is described in this manual, consult BAND-IT.
Operating Tips