Data Capture:
• The tension feedback system can be used with many data capturing devices including any
computer with Windows operating software.
• Any properly equipped tool will work with any I75390 data control box. The tool’s
serial #, clamp count and settings remain with the tool and will be detected by any control box
used. (*the I75390 system will not work with the X75390 system)
• Any software or hardware that can read the stated format can be used to collect data as it is sent
from the tool.
• Updates or customizations to the program in the control box can be sent to the customer using a
single executable file, no other software is required.
Contact BAND-IT Engineering at 800-525-0758.
Tension Cylinder
Pressure Monitoring
System
Example of Data Output:
Program: I75301 Rev A
Pressure: 55 to 75
Force: 336 to 360
Clamp # PSI LBF Tool # Error
30 11111
31 69.1 360 11111
32 64.8 337 11111
33 58.1 302 11111 LOW
34 72.7 378 11111 HIGH
35 69.0 359 11111 C
• LBF = The calculated force applied to the clamp tail +/- 10 LBF.
• One or both of the Pressure and Force rows will display, depending on control box settings. See
page XX for instructions on setting the parameters.
• Clamp number 33 shows a low output and clamp number 34 shows a high output for this example.
• Clamp number 35 shows the data output when the system fails to detect a complete cutoff cycle in
the time allowed. Note that having the tool on the M28090 device will trigger this error.
• Clamp number 30 shows output when tool is first connected.
Incompatible tools:
• In the case that the tool does not have the correct hardware installed the data control box will
output the message “Error! Incompatible tool type detected”
• Contact BAND-IT for information on upgrades.