User Manual

3.2 Technical indicators
3.2.1 Alternating current
Minimum input current 20mA AC current
Maximum input current 10A AC current
Frequency range: 40HZ-1000Hz;
3.2.2 Dc current
Minimum input current 20mA DC current
Maximum input current 10A DC current
3.2.3 Dc voltage
In AUTO mode, the input voltage ranges from 0.5V to 1000V DC
The input voltage ranges from 0.0mV to 999.9mV DC in mV mode
In the mV range, with the input open, the meter may have a
pulsating reading, This is normal because of the high sensitivity
of the meter when connected to the pen When you measure
the circuit, you get a true measurement.
5
Technical indicators
Note:
999.9mA
10A
999.9mA
10A
999.9mV
9.999V
99.99V
999.9V
Range
Resolution
Accuracy
Range
Resolution
Accuracy
Range
Resolution
Accuracy
± (1.0% reading + 8 digits)
± (1.0% reading + 5 digits)
± (
0.5% reading + 3 digits)