Cut Sheet
Table Of Contents
- Contents
- 1 Features
- 2 Overview
- 3 Specifications
- 4 Installation Instructions
- 5 Configuration Instructions
- 5.1 Install the Software
- 5.2 Define the Communication
- 5.3 Alignment
- 5.4 Parameter Setup Files (PSFs)
- 6 Operating Instructions
- 7 Additional Information
- 8 Accessories
- 9 Banner Engineering Corp. Limited Warranty
PSF Conguraon Screen for Models MAC-1, MACP-1, MACN-1,
MACV-1, and MACI-1
PSF Conguraon Screen for Models MAC16N-1 and MAC16P-1
The soware included with the controller makes it easy to congure the MINI-ARRAY using your PC-compable computer. Simply install
the soware, launch the program, and access the Edit PSF Conguraon screen. Each opon is selectable using your mouse and the
pop-up menu-style selecons.
Alarm/Trigger—Output 2 may instead be programmed to serve as a trigger input for another MINI-ARRAY or ALARM for the self-
diagnosc circuitry.
Analog and Discrete Output Assignment—Assigns an analysis (measurement) mode to each output.
Analysis (Measurement) Mode Selecon—Choose the measurement opon that best tells you the size and/or posion of objects as
they relate to the array.
Blanking—Allows either 1 or 2 areas of the array to be blind to the
acvity of the areas specied.
Control Mode Selecon—There are three modes to choose from:
• Connuous Mode: The controller constantly polls the array for status.
• Gate Mode: The controller polls the array for status when prompted by an input from a Gate sensor.
• Host Mode: The controller polls the array for status when prompted by a host controller.
Invert—Allows output to be normally open (No) or normally closed (Yes).
Scan #—Analog outputs are updated with an average value of the data received during the selected number of scans. Discrete outputs
respond only if the received data is idencal for all the selected number of consecuve scans. Values: 1 through 9.
Scanning Method—There are four scanning methods:
• Straight scan polls each beam sequenally to determine the target object's overall size. This is the most accurate and precise
measurement, but also the most me-consuming.
• Interlaced scan alternates a straight scan with a slanted beam scan to improve opcal resoluon in the center one third of the
sensing range.
• Edge scan acvates only the beams located near the top edge of the object in the light screen to reduce the sensing response
me.
• Skip scan skips one to seven beams to reduce the response me. Minimum object detecon size increases proporonally to the
number of beams skipped.
Serial Communicaon—Changes the idencaon and baud rate of the controller being congured.
Serial Transmission—Choose ASCII, binary, or no serial communicaon.
Set Point and Hysteresis Selecon—Assigns the set point to determine where within the array the output(s) will respond and the
hysteresis values to smooth the output response.
Mode
MAC-1, MACP-1, and
MACN-1
MACV-1 and
MACI-1
MAC16N-1 and
MAC16P-1
Analysis Mode Selecon
ALL: All data passed to host x x x
FBB: First Beam Blocked x x x
LBB: Last Beam Blocked x x x
TBB: Total Beams Blocked x x x
CBB: Conguous Beams Blocked x x x
FBM: First Beam Made x x x
LBM: Last Beam Made x x x
A-GAGE
®
MINI-ARRAY
®
Measuring Light Screen System
www.bannerengineering.com - Tel: 763.544.3164 17