Cut Sheet
Table Of Contents
- Contents
- 1 Features
- 2 Overview
- 3 Specifications
- 4 Installation Instructions
- 5 Configuration Instructions
- 5.1 Install the Software
- 5.2 Define the Communication
- 5.3 Alignment
- 5.4 Parameter Setup Files (PSFs)
- 6 Operating Instructions
- 7 Additional Information
- 8 Accessories
- 9 Banner Engineering Corp. Limited Warranty
Model
Null Span
Min Max Min Max
MACV-1 10 mV 2.3 V 4.8 V 10.1 V
MACI-1 3.9 mA 7.8 mA 11.9 mA 20.2 mA
Each output’s Null and Span is independently adjusted using the sliding bars. When the adjustments are made, the new values can be
temporarily monitored by selecng either the Null Update or Span Update buon. Click OK to save the new sengs and return the
controller to normal operaon. Click Cancel to ignore any Null/Span adjustments and return the controller to normal operaon with the
previously saved null and span sengs.
The MAC controller has a four-minute Null/Span me-out feature that causes the controller to leave the Null/Span adjustment
procedure when neither the Null Update nor the Span Update funcons are accessed. When this me-out condion occurs, the MAC
controller automacally cancels the Null/Span adjustment procedure and returns to the previously saved sengs.
5.4.3 Conguring the Blanking Specicaons
Blanking specicaons allow either one or two areas of the array to be blanked (made blind to acvity within that area).
MAC-1, MACP-1, MACN-1, MACV-1, and MACI-1 Controller Models
Beams are numbered from the
boom (cable end) of the sensors to the top of the sensors. The Low beam number and the High beam
number can be designated to dene a Field to be blanked. Zeros are used as default sengs to signify no blanking.
MAC16P-1 and MAC16N-1 Controller Models
The controller can specify blanking of any light channel and save these specicaons in stac memory. Blanking opons are changed
using the supplied soware.
Under the MINI-ARRAY tasks, select the Alignment funcon to access the Alignment screen. Click Start to scan and update the
Alignment screen.
Available blanking commands include: Clear Blanking Fields, Restore Controller Sengs, Auto Blanking, Abort Auto Blanking, Save to
File, Read From File, Cancel, OK, and Edit.
• Clear Blanking Fields removes all blanking specicaons.
• Restore Controller Sengs reads the previously saved blanking specicaons from the MINI-ARRAY controller.
• Auto Blanking selects all blocked channels for blanking. When the Auto Blanking feature is selected, the sengs may be
accepted or aborted.
• Abort Auto Blanking cancels Auto Blanking.
• File Save and File Retrieve allow the user to save and retrieve blanking data to a
le.
• The OK buon saves the new blanking conguraon to the controller. Aer the OK buon is selected, Restore Controller
Sengs will reect the new blanking conguraon.
• The Cancel buon prevents the new blanking conguraon from being saved.
• The Edit funcon allows individual beams to be blanked by launching the Channel Blanking Edit screen.
The Channel Blanking Edit screen groups the beams into rows with a check box for each beam. For instance, the rst row is labeled
1-16. The rst check box represents the blanking state of channel 1. A check mark indicates that the channel has been selected for
blanking.
The Blank Selected/Clear Selected feature allows the user to select/clear rows of channels.
The OK
buon adds the new blanking addions to the Alignment screen.
The Cancel buon voids the Edit changes.
A-GAGE
®
MINI-ARRAY
®
Measuring Light Screen System
www.bannerengineering.com - Tel: 763.544.3164 21