6 Operang Instrucons
6.1 Status Indicators for the MINI-ARRAY Sensors
Note: Status indicators appear to “freeze” if the controller has been congured for the Gate or the Host Mode and there is no
signal to cause a scan update.
Green
Red
Amber
Figure 6. Receiver LEDs
Red On Red O Red Flashing Emier Status
X Emier has power and is funconing properly.
X
Emier failure. The controller's red DIAG 3 indicator should come ON when the red LED on the emier goes OFF. Run
the Diagnoscs soware to determine the cause of the emier failure.
X
Emier has momentarily lost and then regained power and is waing for acvity from the controller. This can occur in
Gate or Host Mode aer the emier has been temporarily unplugged and then reconnected, but before the emier
receives its next gang command.
Green On
Green
Flashing
Amber On Red On Receiver Status
X Receiver is in proper alignment and no beams are broken.
X
Receiver has momentarily lost and then regained power and is waing for acvity from the controller.
This can occur in Gate or Host Mode aer the receiver has been temporarily unplugged and then
reconnected, but before the receiver receives its next gang command.
X X
Marginal alignment. The MINI-ARRAY System connues to operate normally, but the amber comes ON as
an early warning of possible signal loss due to gradual sensor misalignment and/or dirt buildup on the
lenses, etc.
X Either one or more beams are blocked or the sensor is misaligned if the screen is clear of objects.
X X X Receiver failure. Run the Diagnoscs soware to determine the cause of the receiver failure.
6.2 Status Indicators for the MACx-1 Series Controllers
Indicator
LED Color Funcon
Output 1 (labeled OUT1, V out, I out,
OUT or OUT 1 depending on model)
Red
Models MAC-1, MACP-1, MACN-1, MACV-1, MACI-1: displays the status of Output #1
Models MAC16N-1 and MAC16P-1: displays the status that at least one output is acve
Alarm Red
Models MAC-1, MACP-1, MACN-1, MACV-1, MACI-1: displays the status of Output #2. Output #2 may be
assigned to an Analysis Mode or may be used as a system diagnoscs Alarm, or as a Trigger alarm for gang
another MINI-ARRAY System
Models MAC16N-1 and MAC16P-1: displays the status of Output #16
Gate Red Displays the status of the Gate input
A-GAGE
®
MINI-ARRAY
®
Measuring Light Screen System
www.bannerengineering.com - Tel: 763.544.3164 25