3 Specicaons
3.1 Specicaons for the Emier/Receiver Pairs
Range (9.5 mm Beam Spacing)
0.6 m to 6.1 m (2 to 20 ) for sensors < 4
0.6 m to 4.6 m (2 to 15 ) for sensors > 4
Maximum range is specied at the point where 3× excess gain remains.
Minimum Object Sensivity (9.5 mm Beam Spacing)
19.1 mm (0.75 in)
Interlaced Mode: 12.7 mm (0.5 in)
Assumes sensing is in middle one-third of scanning range.
Supply Voltage and Current (Emier)
0.10 amps at 12 V dc
Maximum current is for a 6 sensor.
Status Indicators (Emier)
Red LED lights for proper operaon
Construcon
Aluminum housing with black anodized nish; acrylic lens cover
Range (19.1 mm Beam Spacing)
0.9 m to 17 m (3 to 55 ) for sensors < 4
0.9 m to 14 m (3 to 45 )for sensors > 4
Maximum range is specied at the point where 3× excess gain remains.
Minimum Object Sensivity (19.1 mm Beam Spacing)
38.1 mm (1.5 in)
Interlaced Mode: 25.4 mm (1 in)
Assumes sensing is in middle one-third of scanning range.
Supply Voltage and Current (Receiver)
9.5 mm beams: 0.75 amps at 12 V dc maximum
19.1 mm beams: 0.50 amps at 12 V dc maximum
Maximum current is for a 6 sensor.
Status Indicators (Receiver)
Green: sensors aligned (> 3× excess gain)
Amber: marginal alignment (1×-3× excess gain)
Red: sensors misaligned or beam(s) blocked
Sensor Scan Time
55 microseconds per beam, plus 1 millisecond processing me per scan
Assumes straight scan, connuous scan, and TBB mode
Environmental Rang
NEMA 4, 13 (IEC IP65)
Operang Condions
−20 °C to +70 °C (−4 °F to +158 °F)
95% maximum
relave humidity (non-condensing)
Connecons
Emier and receiver connect to controller using two 5-conductor quick-
disconnect cables (one each for emier and receiver), ordered separately.
Cables measure 8.1 mm (0.32 in ) dia., and are shielded and PVC-jacketed;
conductors are 20-gauge.
Use only Banner cables, which incorporate a "“twisted pair” for noise immunity
on RS-485 data communicaon lines.
Emier and receiver cables may not exceed 250 each.
3.2 Dimensions for the
Emiers and Receivers
With Mounng Bracket Flanges Out With Mounng Bracket Flanges In
L1
L2
X
18.3 mm
[0.72”]
2.5 mm
[0.10”]
L3
10.2 mm
[0.4”]
38.1 mm square
[1.5”]
Housing Length Distance Between Bracket Holes
Emier/Receiver Models L1 L2 L3
BMEL6..A / BMRL6..A 201 mm (7.9 in) 233.9 mm (9.21 in) 177 mm (6.97 in)
BMEL12..A / BMRL12..A 356 mm (14 in) 389.7 mm (15.35 in) 332.8 mm (13.1 in)
BMEL18..A / BMRL18..A 505 mm (19.9 in) 538.7 mm (21.22 in) 481.8 mm (18.97 in)
BMEL24..A / BMRL24..A 659 mm (26 in) 693.2 mm (27.31 in) 636.3 mm (25.05 in)