Cut Sheet
Table Of Contents
Specifications
Supply Voltage
18 V DC to 30 V DC
Supply Current
Indicator Models:
33 mA maximum current at 18 V DC
28 mA typical at 24 V DC
Touch Models:
40 mA maximum current at 18 V DC
30 mA typical at 24 V DC
Supply Protection Circuitry
Protected against reverse polarity and transient voltages
Touch Dwell Time
If touch dwells for longer than 60 seconds, the output will revert to the
untouched state
Operating Conditions
–40 °C to +50 °C (–40 °F to +122 °F)
Humidity: 90% at +50 °C maximum relative humidity (non-condensing)
Storage: –40 °C to +70 °C (–40 °F to +158 °F)
Environmental Rating
IEC IP67, IP69K per DIN 40050-9
1
Mounting
M22 × 1.5 threaded base, maximum torque 4.5 N·m (40 in·lbf)
Construction
Base, Dome, and Nut: Polycarbonate
Touch Response Time
Input Response: 5 ms minimum
Touch Response: 300 ms maximum (Standard Sensitivity touch response)
Vibration and Mechanical Shock
Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 1.0 mm
amplitude, 5 minutes sweep, 30 minutes dwell)
Meets IEC 60068-2-27 requirements (Shock: 30G 11 ms duration, half sine
wave)
IO-Link Interface
Supports Smart Sensor
Profile: No
Baud Rate: 38400 bps (COM2)
Process Data Out: 64 bits (8 bytes)
IODD Files: Provides all programming options, plus additional functionality
Connections
Integral 4-pin M12/Euro-style male quick disconnect or 150 mm (6 in) PVC
cable with a 4-pin M12/Euro-style male quick disconnect, depending on
model
Models with a quick disconnect require a mating cordset
Certifications
Only applies to
K30PL models
Only applies to K30PL
models
Default Indicator Characteristics
Color
Dominant
Wavelength
(nm) or Color
Temperature
(CCT)
Color
Coordinates
2
Lumen Output
(Typical at 25 °C)
x y
Touch
Button
Models
Indicator
Models
Green 522 0.154 0.700 7.7 8.7
Red 620 0.689 0.309 3.1 3.6
Yellow 576 0.467 0.463 7.8 8.9
Blue 466 0.140 0.054 1.7 1.9
White 5700K 0.328 0.337 9.6 10.7
Cyan 493 0.157 0.331 8.7 9.9
Magenta – 0.392 0.186 4.2 4.6
Amber 589 0.556 0.420 5.8 6.4
Rose – 0.525 0.237 3.5 3.9
Lime
Green
562 0.383 0.523 10 11.5
Sky Blue 486 0.145 0.240 9.2 10.5
Orange 599 0.616 0.370 4.6 5.1
Violet – 0.224 0.099 3.4 3.9
Spring
Green
508 0.155 0.524 8 9
Required Overcurrent Protection
WARNING: Electrical connections must be
made by
qualified personnel in accordance with
local and national electrical codes and
regulations.
Overcurrent protection is required to be provided by end product
application per the supplied table.
Overcurrent protection may be provided with external fusing or via Current
Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Supply Wiring (AWG)
Required Overcurrent Protection (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
1
QP models must be installed to protect the cable and cable entrance from high-pressure spray to meet IP69K.
2
Refer to the CIE 1931 (x,y) Chromaticity Diagram to show equivalent color with indicated color coordinates. Actual coordinates may differ ± 5%.
K30 Pro Devices with IO-Link
P/N 215851 Rev. C www.bannerengineering.com - Tel: + 1 888 373 6767 5