Cut Sheet

Quick Start Guide
Laser distance sensor with both analog and discrete (switched) outputs
This guide is designed to help you set up and install the LTF Time of Flight Laser Distance Sensor. For complete informaon on
programming, performance, troubleshoong, dimensions, and accessories, please refer to the Instrucon Manual at
www.bannerengineering.com. Search for p/n 194135 to view the manual. Use of this document assumes familiarity with pernent
industry standards and pracces.
WARNING: Not To Be Used for Personnel Protecon
Never use this device as a sensing device for personnel protecon. Doing so could lead to serious injury or death.
This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety
applicaons. A sensor failure or malfuncon can cause either an energized or de-energized sensor output
condion.
Features and Indicators
Analog Output
LED Indicator
Power
LED Indicator
Discrete Output
LED Indicator
Up and Down
Buttons
Enter Button
Escape Button
Display
Figure 1. Features
Three LED indicators provide ongoing indicaon of the sensing
status.
Analog Output LED Indicator
Solid Amber = Displayed distance is within the taught analog
output window
O = Displayed distance is outside the taught analog output
window
Power LED Indicator
Solid Green = Normal
operaon, power On and laser On
Flashing Green (1 Hz) = Power On and laser O (laser enable
mode)
Discrete Output LED Indicator
Solid Amber = Discrete Output is On
O = Discrete Output is O
Display
Figure 2. Display shown in Run Mode
The display is a 2-line, 8-character LCD. The main screen is the Run
mode screen, which shows the real-me distance measurement
and the analog output measurement.
Buons
Use the sensor buons Down, Up, Enter, and Escape to program the sensor and to access sensor informaon.
L-GAGE
®
LTF Time of Flight Laser Distance Sensor
Original Document
194136 Rev. D
7 June 2017
194136