Cut Sheet
The pole is held securely in its base by four bolts (included). The base bolts to a flat surface with user-supplied 5/16" or M8
hardware. The base plate has four threaded holes for leveling bolts. The mounting design allows the sensor or mirror to easily slide
up or down the pole and then lock into position by tightening four screws.
The following items are included with each MSA Series Stand:
• Clear anodized extruded aluminum pole (qty 1)
• Black epoxy-painted welded steel base assembly (qty 1)
• Post level (qty 1)
• Black zinc-plated steel adapter plate (qty 2)
• M10 × 1 × 18 mm-long slotted/Phillips hex head bolt (qty 4)
• M4 × 0.7 × 10 mm-long slotted hex head screw (qty 12)
• M4 “T” nut (qty 8) (extra screws and T-nuts are included to accommodate mounting of center bracket used with longer
sensors)
Note: Adapter bracket EZA-MBK-2 is required for mounting EZ-SCREEN Points, SGS Grids, or SSM-Series
mirrors. Refer to those product datasheets for more information.
Install the Base and Pole
WARNING:
• Maintain the required separation distance
• Failure to correctly calculate this distance and failure to maintain minimum separation distance can
result in serious injury or death.
• The light screen produced by the optical safety system sensors must be placed at a minimum safe
distance from the dangerous motion of the machine being guarded. This necessary minimum distance
is called the separation distance and is discussed in the appropriate instruction manuals.
127 mm
(5.0")
127 mm
(5.0")
102 mm
(4.0")
51 mm
(2.0")
44.5 mm
(1.75")
Square
51 mm
(2.0")
10º
10º
45º
13 mm
(0.5")
ø127 mm (5.0")
102 mm
(4.0")
4x 0.397"
4x 0.397"
4x M10 x 1.0
Figure 1. Stand base mounting hole pattern
1. Secure the base to the floor or other flat surface using 5/16-inch or M8 hardware, supplied by the installer. Place the base
on its mounting hardware, but do not tighten.
2. Install an M10 leveling bolt (supplied) into each of the four threaded holes for leveling purposes.
3. Using the post level (supplied), adjust the leveling bolts for true vertical level. Continue to check the vertical level of each
pole while tightening the base mounting hardware.
Mount the Sensor or Mirror to the Pole
1. Verify that all poles used for the light screen installation are exactly parallel to each other before mounting sensors and/or
mirrors.
MSA Series Stand
2 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 43687 Rev. D