Sensitivity Selection
* Default settings
B1 B2 B3 Sensitivity
0* 0* 0* 8 (Highest)
0 0 1 7...
0 1 0 6 (High)
0 1 1 5...
1 0 0 4 (Medium)
1 0 1 3...
1 1 0 2 (Low)
1 1 1 1 (Lowest)
NOTE: Operation at a high sensitivity not guaranteed for a zone set beyond 45 m (147.6 ft)
Response Speed
* Default settings
B4 B5 B6 ON Total OFF Total Total
0 0 0 15 15 30
0 0 1 30 70 100
0 1 0 30 120 150
0* 1* 1* 50 300 350
1 0 0 50 600 650
1 0 1 30 1000 1030
1 1 0 120 600 720
1 1 1 120 6000 6120
Output Configuration
* Default settings
A8 NPN / PNP
0* NPN
1 PNP
B7 Normally Open / Closed
0* NO
1 NC
R-GAGE Q120RA-AF2 Sensor