Cut Sheet
Table Of Contents
Specicaons
Supply Voltage and Current
Q60BB6LAF models: 10 to 30 V dc (10% maximum ripple) at less than 50 mA
exclusive of load
Q60VR3LAF Universal models: 12 to 250 V dc or 24 to 250 V ac, 50/60 Hz
Input power: 1.5 W maximum
Supply Protecon Circuitry
Protected against reverse polarity and transient voltages
The dc wiring for model Q60VR3 is without regard to polarity
Output Conguraon
Q60BB6LAF models: Bipolar; one NPN (current sinking) and one PNP (current
sourcing) open-collector transistor
Q60VR3LAF cabled model: E/M Relay (SPDT), normally closed and normally
open contacts
Q60VR3LAFQ1 (QD) model: E/M Relay (SPST), normally open contact
Output Rang—Q60BB6LAF models
150 mA maximum each output @ 25 °C
O-state leakage current: < 5 μA @ 30 V dc
Output saturaon NPN: < 200 mV @ 10 mA and < 1 V @150 mA
Output saturaon PNP: < 1 V at 10 mA; < 1.5 V at 150 mA
Output Rang—Q60VR3LAF Universal models
Minimum voltage and current: 5 V dc, 10 mA
Mechanical life of relay: 50,000,000 operaons
Electrical life of relay at full resisve load: 100,000 operaons
Maximum switching power (resisve load):
Cabled models: 1250 VA, 150 W
QD models: 750 VA, 90 W
Maximum switching voltage (resisve load):
Cabled models: 250 V ac, 125 V dc
QD models: 250 V ac, 125 V dc
Maximum switching current (resisve load):
Cabled models: 5 A @ 250 V ac, 5 A @ 30 V dc derated to 200 mA @ 125 V
dc
QD models: 3 A @ 250 V ac, 3 A @ 30 V dc derated to 200 mA @ 125 V dc
Output Protecon Circuitry
Q60BB6LAF models: Protected against connuous overload or short circuit of
outputs
All models: Protected against false pulse on power-up
Note: 1 second maximum delay at power up
(outputs do not conduct during this me)
Output Response Time
Q60BB6LAF models: 2 milliseconds ON and OFF
Q60VR3LAF Universal models: 15 milliseconds ON and OFF
Repeatability
500 microseconds
Sensing Hysteresis
See Figure 11 on page 5
Laser Characteriscs
Spot Size:
approximately 4 × 2 mm throughout range (collimated beam)
Angle of Divergence: 5 milliradians
Note: Contact Banner Engineering for a custom
laser spot size.
Adjustments
Sloed, geared, 2-turn, cuto range adjustment screw (mechanical stops on
both ends of travel)
2 momentary push buons: ON Delay (+) and OFF Delay (–); DC models also
have a remote program wire
ON Delay select: 8 ms to 16 seconds
OFF Delay select: 8 ms to 16 seconds
LO/DO select
Push buon lockout for security
Laser Enable/Disable (remote wire only)
Construcon
Housing: ABS polycarbonate blend
Lens: Acrylic
Environmental Rang
IEC IP67; NEMA 6
Connecons
Q60BB6LAF models: 2 m (6.5 ) or 9 m (30 )
aached cable, 5-pin Euro-style
integral QD, or 5-pin Euro-style 150 mm (6 in) QD
Q60VR3LAF Universal models: 2 m (6.5 ) or 9 m (30 ) aached cable, or 5-
pin Micro-style 150 mm (6 in) QD
Operang Condions
Temperature:
Q60BB6LAF models: −10 °C to +50 °C (+14 °F to +122 °F)
Q60VR3LAF Universal models: −10 °C to +45 °C (+14 °F to +113 °F)
90% at +50 °C maximum relave humidity (non-condensing)
Required Overcurrent Protecon
WARNING: Electrical connecons must be made
by
qualied personnel in accordance with local
and naonal electrical codes and regulaons.
Overcurrent protecon is required to be provided by end product applicaon
per the supplied table.
Overcurrent protecon may be provided with external fusing or via Current
Liming, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For
addional product support, go to www.bannerengineering.com.
Supply Wiring (AWG) Required Overcurrent Protecon (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
Cercaons
Q60LAF Series Laser Adjustable-Field Sensors
P/N 114348 Rev. A www.bannerengineering.com - Tel: +1-763-544-3164 9