Owner manual

D11E Series
Banner Engineering Corporation page 5
DC Product Specifications
Required Fiber Optic Cable
Adjustments Push button teach mode sensitivity setting (see "TEACH mode" information); Remote teach mode input is
provided
Output Configuration One (SPST) NPN (sinking) or PNP(sourcing) open-collector transistor, depending on model; Programmable for
light or dark operate
Output Rating 150 mA maximum;
Off-state leakage current: <5 microamps at 30V dc;
On-state saturation voltage: <0.8V at 80 mA dc; <1.5V at 150 mA dc
Output Protection Circuitry Protected against false pulse on power-up and continuous overload or short-circuit
Output Response Time 200 microseconds (0.2 milliseconds) "on" and "off" (40 milliseconds "off" when pulse stretcher is
programmed) NOTE: 100 millisecond delay on power-up: output is non-conducting during this time
Indicators Three LEDs: Green, Yellow and Red
Green LED lights for dc power "ON" and flashes when ready to register sensing condition during TEACH
mode; 1 Hz when waiting to learn first sensing condition; 2 Hz when waiting to learn second sensing
condition, 4 Hz when output is overloaded
Yellow LED lights for output "ON" (conducting)
Red LED is Banner's patented Alignment Indicating Device (AID™, U.S. patent #4356393) which lights
whenever the sensor "sees" a light condition and superimposes a pulse rate which is proportional to the
strength of the received light signal (the stronger the signal, the faster the pulse rate)
Output Timing Functions ON/OFF (no delay) or fixed 40 millisecond OFF-Delay pulse stretcher; selected by push button
Construction Black ABS (Cycolac
®
KJB) flame retardent housing with acrylic cover; Stainless steel M3 x 0.5 hardware for use
with ABS (Cycolac
®
KJB) mounting bracket (supplied)
Environmental Rating IEC IP54; NEMA 2
Connections 2 m (6-1/2 ft) or 9 m (30 ft) attached cable, or 4-pin pico-style quick-disconnect fitting; Cables for QD
models are purchased separately
Operating Temperature -10º to +55ºC (-14º to +131ºF); Maximum relative humidity 90% at 50ºC (non-condensing)
PI or PB Series plastic fibers
Supply Voltage and Current 5V dc (±10%) at less than 45 mA, exclusive of load
Sensing Beam Visible red, 680 nm
Cycolac
®
is a registered trademark of General Electric Company
WARNING
These photoelectric presence sensors do NOT include the self-checking redundant circuitry
necessary to allow their use in personnel safety applications. A sensor failure or malfunction can result in either
an energized or a de-energized sensor output condition.
Never use these products as sensing devices for personnel protection. Their use as a safety device may create
an unsafe condition which could lead to serious injury or death.
Only MINI-SCREEN
, MULTI-SCREEN
, MACHINE-GUARD and PERIMETER-GUARD Systems, and other systems so designated,
are designed to meet OSHA and ANSI machine safety standards for point-of-operation guarding devices. No other Banner
sensors or controls are designed to meet these standards, and they must NOT be used as sensing devices for personnel
protection.
!