Owner manual
Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 Telephone: (612) 544-3164 FAX (applications) (612) 544-3573
D11E Series
Remote Programming
The white wire of the D11E may be connected to a remote switch for the following sensor programming functions:
1) Disable or enable the push button
2) TEACH mode programming of sensitivity
3) Enable or disable the 40-millisecond pulse stretcher.
A remote programming switch is connected
between the white wire and dc common
(see hookup diagrams on page 6). The
switch may be either a normally-open
contact, or an open-collector NPN transistor
which has its emitter connected to dc
common.
Programming is accomplished using a
specified sequence of input pulses. The
duration of each pulse is defined as:
0.04 seconds < T < 0.8 seconds.
The required spacing between adjacent
pulses in a sequence (e.g. a “double-pulse”)
is: 0.04 < T < 0.8 seconds. The timing
diagrams, (right) illustrate the input
requirements.
Single-Pulse
Input
Wait > 0.8 seconds before next input
0.04 sec ≤ T < 0.8 sec
T
Two-Pulse
Input
Wait > 0.8 seconds before next input
T
T
T
Four-Pulse
Input
Wait > 0.8 seconds before next input
T
T T T
T T T
Disable or Enable the Push Button:
When remote programming is used, exclusively, it may be beneficial to disable the push button on the D11E to increase the
security of the settings.
1) To disable the push button:
Pulse the remote input four times (see timing diagram, above).
2) To enable the push button at a later date:
Pulse the input four times (again).
Set Sensitivity via the TEACH mode:
1) Present the first (output “on”) sensing condition to the sensor and pulse the remote input once.
2) Present the second (output “off”) sensing condition to the sensor and pulse the remote input once. The three LED
indicators will flash simultaneously one to four times to indicate relative sensing contrast (see page 3), and the sensor
will return to RUN mode.
Enable or Disable the 40-millisecond Pulse Stretcher:
1) Pulse the remote input two times (see timing diagram). The status of the pulse stretcher is indicated by the red LED:
The red LED will be lit, steadily, if the pulse stretcher is “on”; the red LED will double-flash if the pulse stretcher is “off”.
2) Pulse the remote input once to toggle the the pulse stretcher “on” or “off”.
3) Pulse the remote input two times to save the setting and return to the RUN mode.
WARRANTY: Banner Engineering Corporation warrants it products to be free from defects for one year. Banner
Engineering Corporation will repair or replace, free of charge, any product of its manufacture found to be defective at the time
it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper
application of Banner products. This warranty is in lieu of any other warranty either expressed or implied.