User Manual

D11E Series Sensors
– Visible Green, Blue or White LED Light Source
page 5
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
D11E Expert Series Specifications
Required Fiber Optic Cable
Adjustments Push-button TEACH-mode sensitivity setting (see TEACH Mode information); remote TEACH-mode input
is provided
Supply Protection Circuitry Protected against reverse polarity and transient voltages
Output Configuration One (SPST) NPN (sinking) or PNP (sourcing) open-collector transistor, depending on model;
Programmable for light or dark operate
Output Rating 150 mA maximum;
OFF-state leakage current: < 5 microamps at 30V dc;
ON-state saturation voltage: < 1V at 10 mA dc; < 1.5V at 150 mA dc
Output Protection Circuitry Protected against false pulse on power-up and continuous overload or short-circuit
Output Response Time 200 microseconds (0.2 milliseconds) ON and OFF (40 milliseconds OFF when pulse stretcher is
programmed). NOTE: 100 millisecond delay on power-up; output does not conduct during this time
Indicators Three LEDs: Green, Yellow and Red
Green LED lights for dc power ON and flashes when ready to register sensing condition during TEACH
mode: 1 Hz when waiting to learn first sensing condition, 2 Hz when waiting to learn second sensing
condition, 4 Hz when output is overloaded
Yellow LED lights for output ON (conducting)
Red LED is Banner’s patented Alignment Indicating Device (AID™, U.S. patent #4356393) which lights
whenever the sensor “sees” a light condition and superimposes a pulse rate which is proportional to
the strength of the received light signal (the stronger the signal, the faster the pulse rate)
Output Timing Functions ON/OFF (no delay) or fixed 40 millisecond OFF-Delay pulse stretcher; selected by push button
Sensing Beam Visible green, 525 nm; visible blue, 470 nm; visible white, 450-650 nm
Construction Black ABS (Cycolac
®
KJB) flame-retardant housing with acrylic cover; Stainless steel M3 x 0.5 hardware for use
with ABS (Cycolac
®
KJB) mounting bracket (supplied)
Environmental Rating IEC IP54; NEMA 2
Connections 2 m (6.5') or 9 m (30') attached cable, or 4-pin Pico-style quick-disconnect fitting; cables for QD models
are purchased separately
Operating Conditions Temperature: -10° to +55°C (-14° to +131°F)
Maximum relative humidity: 90% at 50°C (non-condensing)
Repeatability 65 microseconds
PI or PB Series plastic fibers
Supply Voltage and Current 10 to 30V dc (10% maximum ripple) at less than 45 mA, exclusive of load
Certifications
Cycolac
®
is a registered trademark of General Electric Company.
WARNING . . .
Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current
Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
!