Installation guide

Method Action Result
SET Button a. Present the first condition.
b. Click the SET rocker button
Display: Flashes "2Pt tch" then holds
on "1234 2nd"
Remote Input a. Present the first condition.
b. Single-pulse the remote input.
T
3. Teach the second condition.
Method Action Result
SET Button a. Present the second condition.
b. Click the SET rocker button.
TEACH Accepted
Displays alternate "PASS" and %
Minimum Difference
4
; Sensor returns
to Adjust mode
TEACH Not Accepted
Displays alternate "FAIL" and %
Minimum Difference
4
; Sensor returns
to Adjust mode
Remote Input a. Present the second condition.
b. Single-pulse the remote input.
T
4. Return to Run mode.
Method Action Result
SET Button Move the Mode switch to RUN
Display: Red - Signal Level; Green -
Threshold
Remote Input No action is required; sensor returns to
RUN mode automatically
Dynamic TEACH
Teaches on-the-fly
Establishes a single switching threshold
Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
Dynamic TEACH is best used when a machine or process may not be stopped for teaching. The sensor learns during actual
sensing conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at the
optimum level (see Figure 3 on page 9).
4
See Troubleshooting on page
18 for more explanation of the % Minimum Difference displayed after the Two-Point TEACH
method.
DF-G1 Expert
Dual Display Fiber Amplifier