Instruction manual
Method Action Result
SET Button
2
Set the Mode switch to ADJ.
Display: Red - Signal Level; Green -
Threshold
Remote Input
3
No action is required; sensor is ready
for the Two-Point TEACH method
2. Teach the first condition.
Method Action Result
SET Button a. Present the first condition.
b. Click the SET rocker button
Display: Flashes "2Pt tch" then holds
on "1234 2nd"
Remote Input a. Present the first condition.
b. Single-pulse the remote input.
T
3. Teach the second condition.
Method Action Result
SET Button a. Present the second condition.
b. Click the SET rocker button.
TEACH Accepted
Displays alternate "PASS" and %
Minimum Difference
4
; Sensor returns
to Adjust mode
TEACH Not Accepted
Displays alternate "FAIL" and %
Minimum Difference
4
; Sensor returns
to Adjust mode
Remote Input a. Present the second condition.
b. Single-pulse the remote input.
T
4. Return to Run mode.
Method Action Result
SET Button Move the Mode switch to RUN Display: Red - Signal Level; Green -
Threshold
Remote Input No action is required; sensor returns to
RUN mode automatically
2
SET Button: 0.04 seconds ≤ "Click" ≤ 0.8 seconds
3
Remote Input: 0.04 seconds ≤ T ≤ 0.8 seconds
4
See Troubleshooting on page
24 for more explanation of the % Minimum Difference displayed after the Two-Point TEACH
method.
DF-G1 Expert
™
Dual Display Fiber Amplifier
14