Instruction manual
Method Action Result
SET Button
• Present sensing condition
•
Click the SET rocker button
Threshold Condition Accepted
Displays read "wInd SEt" then
alternate "PASS" with % Offset
10
;
Sensor returns to Adjust mode
Threshold Condition Not Accepted
Displays read "wInd SEt" then
alternate "FAIL" with minimum %
Offset
10
for sensing condition; Sensor
returns to Adjust mode
Remote Input
• Present sensing condition
•
Single-pulse the remote input
T
3. Return to RUN Mode
Method Action Result
SET Button Move Mode switch to Run Display: Red - Signal Level; Green -
Window Center (see Figure 8 on page
18
for instructions on how to display
upper and lower thresholds)
Remote Input No action required; sensor returns to
Run mode automatically
Figure 8. Upper and Lower Thresholds
6.4 Light SET
• Sets a threshold a programmable % offset below the presented condition
•
Changes output state on any condition darker than the threshold condition
• Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
• Recommended for applications where only one condition is known, for example a stable light background with
varying darker targets
• See Program Mode on page 9 for programming the Offset Percent setting
10
See Troubleshooting on page
24 for more explanation of the % Offset displayed after the Window SET method
DF-G1 Expert
™
Dual Display Fiber Amplifier
18