Instruction manual
8 Specifications
Sensing Beam
660 nm visible red
Supply Voltage
NPN/PNP models: 10 to 30 V dc Class 2 (10% max ripple)
IO-Link models: 18 to 30 V dc (10% max ripple)
Power and Current Consumption (exclusive of load)
Standard display mode:
960 mW, Current consumption < 40 mA at 24
V dc
ECO display mode: 720 mW, Current consumption < 30 mA at 24 V dc
Supply Protection Circuitry
Protected against reverse polarity, overvoltage, and transient voltages
Delay at Power Up
500 milliseconds max.; outputs do not conduct during this time
Output Configuration
NPN/PNP models: 1 current sinking (NPN) or 1 current sourcing (PNP)
output, depending on model
IO-Link models: 1 push-pull and 1 PNP (complementary outputs)
Output Rating
100 mA max. load (derate 1 mA per °C above 30 °C)
OFF-state leakage current: NPN/PNP models: < 5 μA at 30 V dc;
IO-Link models: < 50 μA at 30 V dc
ON-state saturation voltage: NPN: < 1.5 V; PNP /IO-Link: < 2 V
Output Protection
Protected against output short-circuit, continuous overload, transient
over-voltages, and false pulse on power up
Output Response Time
High Speed: 200 µs
Standard: 500 µs
Long Range: 2 ms
Extra Long Range: 5 ms
Repeatability
High Speed: 66 µs, Standard/Long Range/Extra Long Range: 100 µs
Connections
PVC-jacketed 2 m or 9 m (6.5 ft or 30 ft) 4-wire integral cable or integral
4-pin Pico-style QD or Pico-style 150 mm (6 in) pigtail QD or Euro-style
150 mm (6 in) pigtail QD
Construction
Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear
polycarbonate cover
Indicators
Red 4-digit Display: Signal Level
Green 4-digit Display: Threshold
(In Program Mode, Red and Green displays are used for programming
menus)
Yellow LED: Output conducting
Environmental Rating
IEC IP50, NEMA 1
Adjustments
3-way RUN/PRG/ADJ Mode Switch
2-way LO/DO Switch
3-way +/SET/- Rocker Button
•
Expert-style teaching (Two-Point and Dynamic TEACH,
Light/Dark/Window/Calibration SET)
• Manually adjust sensitivity (from "+" and "-" rocker button
only)
• Response Speed, TEACH Selection, Offset Percent, Auto
Thresholds, Delays/Timers, Display Readout, Gain
Selection, Factory Defaults (from top panel or remote
input)
• Response Speed, TEACH Selection, Offset Percent, Delays/
Timers, Display Readout, Gain Selection, Factory Defaults
(from top panel or remote input)
• Top panel interface lockout (from remote input only)
Factory Default Settings:
Setting Factory Default
Threshold 2026
TEACH Selection Two-Point TEACH
Response Speed Standard: 500 µs
Offset Percent 10%
Auto Thresholds OFF
OFF Delay 0 (Disabled)
OFF One-Shot 0 (Disabled)
ON Delay 0 (Disabled)
ON One-Shot 0 (Disabled)
Display Readout Numeric, ECO disabled,
Normal Orientation
Gain Selection Auto Gain
Operating Conditions
Temperature: −10 °C to +55 °C (+14 °F to +131 °F)
Storage Temperature: −20 °C to +85 °C (−4 °F to +185 °F)
Humidity: 90% at +60 °C maximum relative humidity (non-
condensing)
IO-Link Interface
Supports Smart Sensor Profile:
Yes
Baud Rate: 38,400 bps (COM2)
Process Data Width: 16 bits
IODD files: Provide all programming options of top panel interface,
plus additional functionality, see IO-Link Interface on page 25
Certifications
Ind. Cont. Eq.
3TJJ
DF-G1 Expert
™
Dual Display Fiber Amplifier
26