7.3.10 Advanced Tab
Use the up and down arrow controls on the Time out field to change the inspection timeout in milliseconds.
Note: When the tool times out, it may have decoded part of the string before the time ran out. This partial
decoding is reported back as the Decoded String. In OCV, whenever a timeout occurs, it is considered
NO MATCH even if the returned Decoded String matched Expected String.
7.3.11 OCV Tool and the Remote Command Channel
Commands
DescriptionSyntax
Sets the expected string, if it is a constant. The
Value should be a quoted string containing
set ocvtool tool_name|tool_number exp_string value|
printable ASCII characters (see Character
Strings 6.2.2.6.1 Character Strings on page
248).
Gets the value of the exptected string.
get ocvtool tool_name|tool_number exp_string