User Manual

Customize the order of the exported data.
Export data from the Vision tools at different times during the inspection.
Customize the “Start Strings” control characters to unique external devices.
Note: The Test tool can have the Communication tool as one of its inputs. Therefore, if a Test
tool is added after the Communication tool, a discrete output can be activated:
If the TCP/IP connection is lost.
If the external device fails to acknowledge it received data.
This output could contribute to an inspection Pass/Fail if it is an input to a Test tool. A Communication tool
without a Test tool will not contribute to the inspection Pass/Fail.
Select
This field provides a drop-down list from which to select tools; select the results to export from the selected
tool’s tab that appears in the configuration window.
Connections
This field provides a drop-down list from which to select the communication connection(s) to export the data.
Format
This field provides options for formatting the ASCII string of data that will be exported.
P/N 000000Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
164
7/2009PresencePLUS Software Tools