User Manual

DescriptionValuesOption Name
and tab to be output
repsectively.
This option is a mechanism for
adding characters after a string of
data.
User-defined ASCII characters
(limit of 75 characters)
End String
Note: ASCII Hex characters
are allowed. Special symbols
such as \r, \n, and \t will cause
a carriage return, new line,
and tab to be output
repsectively.
Check this box to add a label to
the data before the data itself.
Parameter labelsEnable Labels
Example: Dark Count = 3, where
"Dark Count=" is the label.
4. Set conditions for conditionally exporting the selected data (in the Output Filter field).
Select Pass to export the selected information on a passing Test tool.
Select Fail to export the selected information on a failing Test tool.
Communication Tool Exportable Results
The Communication tool sends out the data in the same sequence that the tools appear in the inspection, and
the result of transmitting this data will increase the inspection time.
The following shows the data sent out for each Communication tool.
DescriptionValueResult
Checks the connection (Ethernet
only).
1 = The connection is valid, and
data will be sent.
Success
Processing time for the Sensor
to send the data out.
Given in ms.Execution time
The table below shows the format of the data.
ExampleFormatNumberResult*
(23.41, 156.52)(0.00, 00.00)DecimalPoint (X,Y)
99.0000.00DecimalDistance
40WholeCount
* Available data is tool and model-dependent.
Location Tools
167Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
P/N 000000
PresencePLUS Software Tools7/2009