8.7 Remote Command Channel Configuration
This section describes the commands that are supported to communicate with a Vision sensor. All commands
are case-insensitive
8.7.1 Remote Command Set
All RCC commands are case-insensitive. Valid characters for commands are 7-bit ASCII alphabetic or numeric
characters (A-Z, a-z, 0-9), dash (-) and underscore (_).
All commands have the following structure:
ACTiON OBJECT_IDENTIFIER QUALIFIER(S)
ACTION is an operation the user intends to perform on the OBJECT_IDENTIFIER. There are three possible
actions available:
GET — used to retrieve information associated with the named object. This information can be a
Boolean value, and unsigned or signed number, a string or, for complex objects like the
Communications tool, a field-delimited record that includes other data types.
SET — used to assign a value to a named object.
EXEC — used to execute a pre-defined functional object or activity in the sensor. Activities may
take object identifiers as parameter qualifiers.
The table below identifies objects that are supported in the current RCC release, their identifiers, and the
corresponding actions that they will support. Items highlighted in bold are command keywords. Flag objects
are appended with the FLG suffix, status objects are appended with the STS suffix, and counters are appended
with the CNT suffix.
CommentsOptional
Qualifiers
Required
Qualifiers
Support
Actions
Object or
Activity
Identifier
System
Object,
Component,
or Activity
If no qualifiers
are specified, a
Timeout
(msec)
or
NoneEXECTRIGGERTrigger
30 second
timeout is used.
NOWAIT
By default, a 30
second timeout
is used.
Timeout
(msec)
or
Numeric
Inspection ID
EXECPRODCHANGEProduct
Change
NOWAIT
Reset either the
System Error
NoneSYSERRFLG
or
EXECRESETCounter or
Flag Reset
Flag, Pass and
PASSFAILCNT
Fail counters, or
or
Missing Trigger
count.