User Manual

9.4.4 Remote Teach Results
Remote Teach will indicate normal Pass/Fail results. To clarify normal results, the rules are as follows:
If Location tools were used in the inspection, then they must perform correctly; that is, the Locate
tool must find an edge, and the Vision tool(s) must find a pattern. If they do not perform correctly,
the Remote Teach will fail, andthe inspection will indicate Fail.
Note: If the Remote Teach fails for this reason, then the new pattern will not be taught, and
the previous inspection will still be valid.
If Location tools were used and they performed correctly or if Location tools were not used, then
the Remote Teach will attempt to update the Vision tool (if enabled). If the Vision tool fails, then
the Remote Teach will fail, and the inspection will indicate Fail.
Note: If the Remote Teach fails for this reason, then the existing inspection is not valid. The
Remote Teach inspection will continue to fail until a new inspection is taught or selected (via
Product Change) or until the Sensor is taken out of Run mode.
If the Remote Teach is successful, the inspection will indicate Pass, and the new inspection will
perform with the new parameters.
P/N 000000Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
254
7/2009Teach