User Manual

Cause/SolutionProblem
Ethernet connection lost.
Error message "Failed to capture a full-resolution
image. Please try again." Reconnect the cable.
Image is frozen on PC, but image on monitor updates
properly.Image is frozen on PC, but image on monitor
updates properly.
Check the cable for breaks, then power down and
back up.
Replace the cable.
Indicator lights on RJ-45 port are OFF.
Attempt to close and reopen PresencePLUS
software.
If none of these actions fix the problem, call a Banner
Applications Engineer.
FTP communications is blocked.
Focus number does not update.
Disable TCP/IP Firewall software on the PC.
QuickStart fails.
Errors when saving inspections to the sensor.
A list of error codes and potential causes and
solutions are available in the main help.
Error code is displayed on PC.
3.4 Setting Up Hardware Parameters
If the Sensor is being run for the first time, or if changes have been made to the hardware, then you
may need to set or modify hardware parameters.
1. Click on System in the Main Menu toolbar.
2. Configure the Trigger parameter according to the trigger device being used. For example, if using
the QS18V6ND as the trigger device, then select NPN.
3. Configure the six discrete inputs/outputs.
4. If the controller triggers a strobe light source, set the strobe trigger options.
5. If using the product select, configure the product select and product change lines to be NPN or
PNP as required.
6. Click on Setup in the Main Menu toolbar, select Trigger tab, and configure the remaining
parameters:
Polarity
Minimum Trigger Width
Trigger delay
Trigger Divide
3.5 Building an Inspection
The automatic screen sequence starts with the Setup screen, hich results from the first button (Setup) in the
Main Menu toolbar. Subsequent screens are shown below in the Main Menu toolbar layout.
P/N 000000Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
26
7/2009Getting Started