User Manual

1. Setup screen:
a. Set up the camera, lens, and lighting.
b. Choose trigger option Continuous for a live image.
c. Click Auto-exposure to adjust the image brightness.
d. Focus the lens by turning the lens focusing ring until the focus value is maximized.
e. When the desired image is shown, click Next to proceed to the Tools screen.
2. Tools screen:
a. Add Location tool(s) to find the target to adjust the Regions of Interest (ROI) for translational and rotational
changes.
b. Required: Add Vision tool(s) to inspect the part.
c. Add Measure tools(s) to create distance measurements from points found.
d. Required: Add Test tool(s) to set the Pass/Fail criteria (Vision and Measure tools are inputs to the Test
tool).
e. Click Quick Teach to automatically set all the selected parameters in the Test tool and to proceed to
the Run screen, or click Next to proceed to the Teach screen and to teach a sample set of good products.
Note: To keep specific, user-defined parameters in a Test tool, skip Teach and go directly to Run.
3. Teach screen:
The Teach screen automatically configures the parameters chosen in the Tools screen.
a. Chooose the sample size.
b. Click Start.
c. Trigger the controller with the external trigger device.
d. Click Stop.
Note: Before entering Run, save inspection file to one of the memory locations on the controller.
e. Click Next to proceed to the Run screen.
Note: Save a backup copy of the inspection to the host PC.
4. Run screen:
Select an inspection fo run, and review the results of the inspection.