User Manual

4.4.1 Trigger Settings
DescriptionField
Sets the sequence of valid triggers. If set to 1, an image is captured in response
to every valid trigger; if set to 2, and image is captured in response to every second
valid trigger, and so on.
Trigger Divide (range:
1-10,000 triggers)
Fixed time (ms) from the instant the Sensor receives a valid trigger to the instant
the Sensor captures the image.
Trigger Delay (range:
0-8,000 ms)
Eliminates unwanted triggers by accepting triggers only if they are above a
specified duration.
Minimum Trigger Width
(range: 1-8,000 ms)
Choose Leading Edge to capture images at the leading edge of a trigger signal.
Choose Trailing Edge to capture images at the trailing edge of the trigger signal.
Polarity
33Banner Engineering Corp. - Minneapolis, MN USA - www.bannerengineering.com
Tel: 763.544.3164
P/N 000000
Setup7/2009