User Manual

DescriptionSyntax
Sets the specified tool operand, if it is a
constant. Value should be a quoted string (see
set stringtool tool_name|tool_number operand_1|operand_2
Character Strings 6.2.2.6.1 Character Strings
on page 248).
Gets the value of the specified tool operand, if
it is a constant.
get stringtool tool_name|tool_number operand_1|operand_2
OCV Tool and the Remote Command Channel
Commands
DescriptionSyntax
Sets the expected string, if it is a constant. The
Value should be a quoted string containing
set ocvtool tool_name|tool_number exp_string value|
printable ASCII characters (see Character
Strings 6.2.2.6.1 Character Strings on page
248).
Gets the value of the exptected string.
get ocvtool tool_name|tool_number exp_string
RCC Return Values
RCC return values are numeric, and are listed below:
0 - command accepted. This return code is generated when a valid SET, GET, and EXEC command
has been completely handled by the sensor. It may be followed by a command-specific return value
or a completion code.
If the frame tag is enabled, the current frame number will be returned instead of 0 as command acceptance
indicator.
-100 - Invalid command entered by the user.
Trigger and Product Change error codes:
-201 - Product change command attempted in the middle of the inspection
-202 – Trigger command attempted in the middle of product change
-203 – Trigger command is attempted when the inspection is not executing (sensor is idle)
-204 – Specified inspection slot is out of range
-205 – Trigger command attempted in the middle of the inspection
-206 – Product change command attempted in the middle of a product change
-207 – Product change command attempted while the sensor is in the Teach mode
-208 Product change attempted when the GUI is connected, and the inspection is not executing
Comm tool error codes
-301 – get/set tool command attempted while the inspection is not executing
-302 get command issued before inspection is triggered for the first time tool results unavailable
-303 – get/set tool command attempted in the middle of the inspection
-304 – get/set tool command attempted in the middle of the product change
-305 – Tool specified in get/set command not found in the inspection