User Manual
The lower the number you enter, the faster the inspection time because the inspection will stop once it reaches the
selected number. The maximum number of outline patterns that the tool will find is 255.
Edge Length
The tool ignores target patterns with edges equal to or shorter than the specified number of pixels for edge length.
Legend
All edges found by the Geometric Find tool are color-coded in the Image window. Strong edges show up in green, and
weak edges show up in red.
Note: Both weak and strong edges in the pattern ROI are expected to be present in the inspection.
Results
The Results field returns the following:
• Total number of shapes above the minimum acceptance level.
• Position of each shape's center. The origin (0,0) is the upper-left corner of the screen.
Geometric Count Tool Advanced Tab
Fields in the Geometric Count Tool Advanced tab are described in the following.
Fields
The following are fields on the Geometric Count tool Advanced tab:
• Rotation Range on page 157
• Extra and Missing Edges on page 157
• Minimum Acceptance Level on page 173
• Reject Threshold on page 158
• Scaling Range on page 159
• Results on page 159
Banner Engineering Corp.Minneapolis, MN USA156
2/2010PresencePLUS Software Tools