• -303 – get/set tool command attempted in the middle of the inspection
• -304 – get/set tool command attempted in the middle of the product change
• -305 – Tool specied in get/set command not found in the inspection
• -306 – Requested comm tool is not congured for RCC
• -307 - Tool executed with an error or did not execute
• -308 - Specied tool operand is not a constant, and cannot be modied
• Reset command error codes
• -401 – Reset command attempted in the middle of the inspection
• -402 – Reset command attempted in the middle of the product change
• -500 – RCC commands are not accepted because the sensor is in the Playback mode
• Timeout error codes
• -600 – Product change timeout occurred
• -601 – Trigger timeout occurred
• -700 – Specied value is out of range
• -701 – Set Gain command attempted when the GUI is connected and the inspection is not executing
• -702 – Set Exposure command attempted when the GUI is connected and the inspection is not executing
• -800 – Product Change, Trigger or Get Commtool command attempted when either Product Change or Trigger
Command timeout occurred, but the operation has not yet completed.
Frame Tag Numbers
RCC provides user with a debug facility that allows users to correlate command completion with current frame numbers.
This facility is enabled by issuing a SET FRAMETAG ENABLE command. This command will cause RCC to send
the current frame number as the command acceptance code. This will allow users to track when each command was
issued, and which frame it applies to.
For EXEC TRIGGER command, returned number will be the frame number at the completion of the inspection
execution.
For EXEC TRIGGER command, returned number will be the frame number at the completion of the inspection
execution.
For all other commands, the returned number is the current frame number.
Command Processing
RCC commands are interpreted in the context of the running PPVS system. Due to the constantly changing system
state caused either by external action or by previous RCC commands, certain rules are imposed on RCC command
acceptance and processing. Please note that command acceptance does not constitute successful completion of the
command.
1. EXEC TRIGGER command can be successfully accepted under the following conditions:
• Inspection is Executing and is Ready
2. EXEC PRODCHANGE command can be successfully accepted under the following conditions:
• Sensor is idle (inspection is not loaded), and the GUI is not connected
• Inspection is Executing and is Ready
• Sensor was previously product changed to an invalid slot
3. EXEC RESET command can be successfully accepted under the following conditions:
• Sensor is idle (inspection is not loaded)
• Inspection is Executing and is Ready
4. SET GAIN or SET EXPOSURE commands can be successfully accepted under the following conditions: