Manual

Q40 Sensors – dc-Voltage Series
4 P/N 121516 
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Supply Voltage and 
Current
10 to 30V dc (10% max. ripple); supply current (exclusive of load current):
  Emitters:
 25 mA 
  Receivers: 20 mA 
  Polarized Retroreflective: 30 mA
  Fixed-Field:
 35 mA
Supply Protection 
Circuitry
Protected against reverse polarity and transient voltages
Output Configuration  SPDT solid-state dc switch; NPN (current sinking) or PNP (current sourcing) outputs, depending on model
Light Operate:   N.O. output conducts when sensor sees its own (or the emitter’s) modulated light 
Dark Operate:   N.C. output conducts when the sensor sees dark; the N.C. (normally closed) output may be 
wired as a normally open marginal signal alarm output, depending upon hookup to power supply 
Output Rating  150 mA maximum (each) in standard hookup. When wired for alarm output, the total load may not exceed 150 mA.
OFF-state leakage current: < 1 microamp @ 30V dc
ON-state saturation voltage: < 1V @ 10 mA dc; < 1.5V @ 150 mA dc
Output Protection 
Circuitry
Protected against false pulse on power-up and continuous overload or short circuit of outputs
Output Response Time Opposed mode: 3 ms ON, 1.5 ms OFF 
  Polarized Retro and Fixed-Field:
 3 ms ON and OFF
 NOTE: 100 ms delay on power-up; outputs do not conduct during this time.
Repeatability Opposed mode: 375 µs 
Polarized Retro and Fixed-Field: 750 µs 
Repeatability and response are independent of signal strength.
Indicators
Two LEDs (Green and Yellow)
Green ON steady:  power to sensor is ON 
Green flashing: output is overloaded
Yellow ON steady:  N.O. output is conducting 
Yellow flashing:  excess gain marginal (1 to 1.5x) in light condition
Construction
PBT polyester housing; polycarbonate (opposed-mode) or acrylic lens
Environmental Rating
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)
Connections
 2 m (6.5') or 9 m (30') attached cable or 4-pin Euro-style quick-disconnect fitting 
Operating Conditions Temperature:  -40° to +70° C (-40° to +158° F)
Maximum relative humidity: 90% at 50° C (non-condensing)
Vibration and Mechanical 
Shock
All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double 
amplitude 0.06" acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for 
non-operation)
 Certifications
Specifications