Manual

Datasheet
Positive-opening safety contacts (IEC 60947-5-1), not dependent
upon springs
Both safety contacts latch open when rope is pulled or in case of a
broken wire; requires manual reset
Heavy-duty die cast metal housing, rated IP65, suitable for demanding
industrial environments
Rope spans up to 6 m, 12 m or 20 m (20 ft, 40 ft, or 66 ft), depending
on model
Both safety contacts are closed with normal rope tension; one contact
opens when rope is pulled, the other contact opens if rope breaks (or
if tension is reduced from normal amount)
Some models include extra contacts for monitoring or to provide dual-
channel input to a safety device
Indicator mark on switch shows when rope has proper tension for
operation
Long life, switch rated at 1 million mechanical operations, minimum
Five available models; all with latching outputs
Protective Earth Terminal (IEC 60947-1)
Model Max. Rope
Length
Run Position Cable Pulled Cable Break Switching Diagram
RP-QM72D-6L 6 m (20 ft)
25 26
13 14
25 26
13 14
25 26
13 14
13-14
25-26
Break
Pull
90N
120N
0 (0)
2 (0.08)
4 (0.16)
6 (0.24)
mm (in)
.
RP-QM72D-12L 12 m (40 ft)
25 26
13 14
25 26
13 14
25 26
13 14
13-14
25-26
Break
Pull
150N
240N
0 (0)
1.5 (0.06)
5 (0.20)
7.5 (0.30)
mm (in)
Rope Pull Switches