Instruction Manual

Accuracy
0.5%
Indicators
Green: Power
Amber: IO-Link communications
Amber: Analog input value present
Amber: Analog output value in range
Vibration and Mechanical Shock
Meets IEC 60068-2-6 requirements (Vibration: 10 Hz to 55 Hz, 0.5 mm amplitude, 5
minutes sweep, 30 minutes dwell)
Meets IEC 60068-2-27 requirements (Shock: 15G 11 ms duration, half sine wave)
Certifications
Banner Engineering Europe Park
Lane, Culliganlaan 2F bus 3, 1831
Diegem, BELGIUM
Turck Banner LTD Blenheim
House, Blenheim Court, Wickford,
Essex SS11 8YT, Great Britain
Required Overcurrent Protection
WARNING: Electrical connections must be made by
qualified personnel in accordance with local and
national electrical codes and regulations.
Overcurrent protection is required to be provided by end product application per the
supplied table.
Overcurrent protection may be provided with external fusing or via Current Limiting,
Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to www.bannerengineering.com.
Supply Wiring (AWG) Required Overcurrent Protection (Amps)
20 5.0
22 3.0
24 2.0
26 1.0
28 0.8
30 0.5
Dimensions
All measurements are listed in millimeters [inches], unless noted otherwise.
Accessories
Cordsets
4-Pin Threaded M12 Cordsets—Double Ended
Model Length Style Dimensions Pinout
MQDEC-401SS 0.31 m (1 ft)
Male Straight/Female
Straight
40 Typ.
[1.58"]
ø 14.5 [0.57"]
M12 x 1
44 Typ.
[1.73"]
ø 14.5 [0.57"]
M12 x 1
Female
2
3
4
1
Male
1 = Brown
2 = White
3 = Blue
4 = Black
MQDEC-403SS 0.91 m (2.99 ft)
MQDEC-406SS 1.83 m (6 ft)
MQDEC-412SS 3.66 m (12 ft)
MQDEC-420SS 6.10 m (20 ft)
MQDEC-430SS 9.14 m (30.2 ft)
MQDEC-450SS 15.2 m (49.9 ft)
R45C IO-Link to Dual Analog Input-Output Converter
4 www.bannerengineering.com - Tel: + 1 888 373 6767 P/N 228480 Rev. A