Specifications
Contact Rating 10A @ 24V ac, 10A @ 110V ac, 6A @ 230V ac
6A @ 24V dc
2.5 kV max. transient tolerance
NEMA A300 P300
European Rating Utilization categories: AC15 and DC13
U
i
= 500V ac
I
th
= 10A
40-60 Hz
U
e
V
I
e
/AC-15
A
I
e
/AC-13
A
24 10 6
110 10 1
230 6 0.4
Contact Material Silver-nickel alloy
Maximum Switching Speed 50 operations per minute
Required Actuation Force 15 N cm (1.3 lbf in)
Short Circuit Protection 6 amp Slow Blow, 10 amp Fast Blow. Recommended external fusing or overload protection.
Mechanical Life 1 million operations
Wire Connections Screw terminals with pressure plates accept the following wire sizes
Stranded and solid: 20 AWG (0.5 mm
2
) to 16 AWG (1.5 mm
2
) for one wire
Stranded: 20 AWG (0.5 mm
2
) to 18 AWG (1.0 mm
2
) for two wires
Cable Entry M20 x 1.5 threaded entrance.
Adapter supplied to convert M20 x 1.5 to ½"-14 NPT threaded entrance
(See dimension drawings on page 7.)
Construction Glass fiber-reinforced thermoplastic UL94-VO rating; plated steel actuator
Environmental Rating IEC IP65
Operating Conditions Temperature:
-30° to +80° C (-22° to +176° F)
Weight 0.09 Kg (0.20 lbs)
Certifications