Owner manual

Inputs and Outputs
Analog Inputs
Rating for 0 to 20 mA models: 24 mA
Rating for 0 to 10V models: 10V
Impedance: 100 Ohms
Sample/Report Rates (Analog IN 1): DIP switch config-
urable (see tables)
Sample/Report Rates (Analog IN 2): 1 second/16 sec-
onds
Accuracy: 0.1% of full scale +0.01% per °C
Resolution: 12-bit
Switch Power Outputs
Analog configuration: one
Discrete configuration: two
Host configuration: up to four
To verify the analog input's impedance, use an Ohm meter to
measure the resistance between the analog input terminal (AIx)
and the ground (GND) terminal.
Environmental and Certifications
Rating
DX80 Models:IEC IP67; NEMA 6; (See UL section be-
low for any applicable UL specifications)
DX80...C Models: IEC IP20; NEMA 1 (In a suitable en-
closure: Class I, Division 2, Group A, B, C, D; T4 −40
to 80 °C)
Operating Temperature
−40 to +85 °C (Electronics); −20 to +80 °C (LCD)
Operating Humidity
95% max. relative (non-condensing)
Radiated Immunity
10 V/m, 80-2700 MHz (EN61000-6-2)
Shock and Vibration
IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz
DX8x...C (External Wiring Terminal Models)
CSA: Class I, Division 2, Groups A, B, C, D
(Ex/A Ex nA II T4); Certificate: 1921239
LCIE/ATEX: Zone 2 (II 3G / Ex nA IIC); Certifi-
cate: LCIE 10 ATEX 1012 X
Refer to the SureCross DX80 Wireless I/O Network Product Manual (p/n 132607) for installation and waterproofing instructions. Operat-
ing the devices at the maximum operating conditions for extended periods can shorten the life of the device.
Included with Model
The following items ship with the DX80 radios.
BWA-HW-002: DX80 Access Hardware Kit, containing four PG-7 plastic threaded plugs, four PG-7 nylon gland fittings, four PG-7 hex
nuts, one 1/2-inch NPT plug, and one 1/2-inch nylon gland fitting. (Not included with IP20 DX80...C models)
BWA-HW-001: Mounting Hardware Kit, containing four M5-0.8 x 25mm SS screws, four M5-0.8 x 16mm SS screws, four M5-0.8mm
SS hex nuts, and four #8-32 x 3/4" SS bolts
BWA-HW-003: PTFE tape
BWA-9O2-C (900 MHz) or BWA-2O2-C (2.4 GHz): Antenna, 2 dBd Omni, Rubber Swivel RP-SMA Male. (Not included with Internal
antenna models)
Quick Start Guide (128185 for DX80 Gateways or 152653 for MultiHop models)
MQDC1-506: 5-Euro (single ended) straight cable, 2m (Not included with FlexPower devices)
BWA-HW-011: IP20 Screw Terminal Headers (2 pack) (Included only with the IP20 DX80...C models)
Warnings
Antenna Installations. Install and properly ground a qualified surge suppressor when installing a remote antenna system.
Remote antenna
configurations installed without surge suppressors invalidate the manufacturer's warranty. Keep the ground wire as short as possible and make all
ground connections to a single-point ground system to ensure no ground loops are created. No surge suppressor can absorb all lightning strikes; do
not touch the SureCross® device or any equipment connected to the SureCross device during a thunderstorm.
Exporting SureCross Radios. It is our intent to fully comply with all national and regional regulations regarding radio frequency emissions. Custom-
ers who want to re-export this product to a country other than that to which it was sold must ensure the device is approved in the destina-
tion country. A list of approved countries appears in the Radio Certifications section of the product manual. The SureCross wireless products were
SureCross DX80 FlexPower Node
P/N 131296 Rev. L www.bannerengineering.com - tel: 763-544-3164 9