Introduction
DX80 GatewayPro
1. Industrial Ethernet Port, female
2. Rotary Switch 1 (left) Sets the Network ID (NID) to a hexidecimal value from 0 to F, for a total of 16 Network IDs. A Gateway and
its corresponding Nodes must be assigned the same Network ID.
Rotary Switch 2 (right) Gateway: Sets the Gateway’s LCD viewing device address. The Gateway is predefined as Device Address 0.
Node: Sets the Node’s Device Address (hexidecimal 1 to F). Each Node within a network must have a unique
Node Device Address.
3. Push Button 1 Single-click to advance across all top-level DX80 menus. Single-click to move down interactive menus, once
a top-level menu is chosen.
4. Push Button 2 Double-click to select a menu and to enter manual scrolling mode.
Double-click to move up one level at a time.
5. LED 1 and 2 Provide real-time feedback to the user regarding RF link status, serial communications activity, and the error
state.
6. LCD Display Six-character display provides run mode user information. This display allows the user to conduct a Site
Survey (RSSI) and modify other DX80 configuration parameters without the use of a PC or other external
software interfaces. On the Node, after 15 minutes of inactivity, the LCD goes blank. Press any button to
refresh the display.
7. 5-Pin M12 Euro-style quick-disconnect serial port